<LOGO>
FM Transmitter Measurement Report
Created: 2024-01-18 14-17-21
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.70 MHz 5/5, 34 dBuV R-PCE
Pilot RDS Phase Difference
6.4 kHz 4.0 kHz 79 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
13 kHz 41 kHz 18433 0,0434
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,5 dBr -0,78 dBr -0,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PCE " 280C 9 (Varied) 1 0 1 5 14:17, 18.01.2024
RT
"BELLAMY BROTHERS - LET YOUR LOVE FLOW "
AF EON
98.6, 101.0, 102.4, 104.7 MHz -
FM Scope Max at: 41 kHz MIN: 13 kHz % above 77 kHz: 0,0434 Acquired: 2024/01/18 14:17:18 Total samples: 18433 Equivalent time: 0:15:21 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: -0,3 dBr MIN: -1,5 dBr AVE: -0,78 dBr % above 0,2 dBr: 0,0 Last value: -0,7 dBr (2024/01/18 14:17:18) 14:04 14:06 14:08 14:10 14:12 14:14 14:16 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality